Connectors - Axis I8016-LVE User Manual

Hide thumbs Also See for I8016-LVE:
Table of Contents

Advertisement

AXIS I8016-LVE Network Video Intercom
Specifications

Connectors

Network connector
RJ45 Ethernet connector with Power over Ethernet (PoE).
Audio connector
4-pin terminal block for audio input and output.
Function
Line in
GND
Line out
GND
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm
notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital input - For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
Digital output - For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface, through an event or from the product's webpage.
Function
0 V DC (-)
12 V DC
Configurable
(Input or Output)
Common
Normally
open/normally
closed
Pin
1
2
3
4
Pin
Notes
1
2
3-4
Digital input – Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
Digital output – Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltage transients.
5
6
For connecting relay devices. The relay pin is galvanically
separated from the rest of the circuitry.
Notes
Line in (mono)
Audio ground
Line out (mono)
Audio ground
21
Specifications
0 V DC
Max current = 400 mA
0 to max 30 V DC
0 to max 30 V DC
Max current/voltage = 700mA at 30
V external sourced
Max current/voltage = 700mA at 30
V external sourced