Schema Elettrico Multifilare; Multiwire Wiring Diagram - Beretta Ciao X Installer And User Manual

Hide thumbs Also See for Ciao X:
Table of Contents

Advertisement

Available languages

Available languages

V Lv
TBT
X13
1 2
4
1
X25
X25
X2
X21
X13
4
1
5
1
4
1
ACC1
Elettrodo
A/R
3V
V Hv
X5
X4
3
1
1
2
X6
L-N
IT - ACCESSORI
resistenze antigelo
L-N
EN - ACCESSORIES
antifreeze heaters
8.5

Schema elettrico multifilare

AKJL01: Scheda comando
X1-X25: Connettori di collegamento
ACC1: Trasformatore di accensione
E.A./R.: Elettrodo accensione/rilevazione
F: Fusibile 4A T
3V: Servomotore valvola 3 vie
V Hv: Alimentazione ventilatore 230 V
OPE: Operatore valvola gas
P: Pompa
CE4: Connettore colleg. esterni: (- A B +) Bus 485
S.R.: Sonda ritorno temperatura circuito primario
S.M.: Sonda mandata temperatura circuito primario
S.F.: Sonda fumi
T.L.A.: Termostato limite acqua
T.P.: Trasduttore di pressione
S.S.: Sonda ritorno temperatura circuito sanitario
F.S.: Flussimetro sanitario
V Lv: Segnale controllo ventilatore
T.B.T.: Termostato bassa temperatura
Per effettuare il collegamento del:
TBT = termostato bassa temperatura occorrre tagliare a metà il ponticello colore
bianco marcato con la scritta TBT presente nel connettore 2 poli (X25),
spellare i fili e utilizzare un morsetto elettrico per la giunzione.
FS.
TP
S.S.
1
3
3
1
-t°
12
X9
1
X9
X19
12
1
10
1
X11
AKJL01 GAR
F=4A T
X3
X6
X4
X5
X1
VALVOLA GAS
OPE
OPE
230 V
L
N
P
1
2
3
4
1
2
3
4
5
rosa
6
X1
1
X11
TA: termostato ambiente
TA: room thermostat
S.M.
S.R.
T.L.A.
-t°
-t°
S.F.
-t°
10
X19
1
IT
Valvola gas
EN
Gas valve
Utilizzare contatto
privo di tensione
TA
OT+
X11
SE
X14
nero (-)
5
arancione (A)
giallo (B)
X14
rosso (+24 Vdc)
1
- A B +
CE4 (connettore estraibile
posizionato sotto mensola)
X11
X11
OT+
SE: (sonda esterna)
SE: (outdoor
OT+
temperature sensor)
8.5

Multiwire wiring diagram

AKJL01: Control board
X1-X25: Connection connectors
ACC1: gnition transformer
E.A./R.: Ignition/detection electrode
F: Fuse 4A T
3V: 3-way valve servomotor
V Hv: Fan power supply 230 V
OPE: Gas valve operator
P: Pump
CE4: Connector for ext. connections: (- A B +) Bus 485
S.R.: Temperature return sensor on primary circuit
S.M.: Temperature flow sensor on primary circuit
S.F.: Flue gas sensor
T.L.A.: Water limit thermostat
T.P.: Pressure transducer
S.S.: DHW circuit temperature return sensor
F.S.: Flow meter
V Lv: Fan control signal
T.B.T.: Low temperature limit thermostat
To connect the:
T.B.T. = low temperature thermostat it is necessary to cut in half the white jumper
marked with the word TBT present in the 2-pole connector (X25), strip the
wires and use an electric terminal for the junction.
40
CE4: (connettore estraibile posizionato sotto mensola)
CE4: (removable connector positioned under shelf)
TA: (utilizzare contatto privo di tensione)
Il collegamento del termostato ambiente deve
IT
TA
essere effettuato sul connettore a vite X11 dopo
aver rimosso il ponticello.
Room thermostat: (voltage free contact input)
The connection of the room thermostat must be
EN
made on the screw connector X11 after removing
the jumper.
IT
EN
NOTA: LA POLARIZZAZIONE
"L-N" CONNECTION IS
L-N È CONSIGLIATA
ADVISABLE
Blu
Blue
Marrone
Brown
Nero
Black
Rosso
Red
Bianco
White
Rosa
Pink
Arancione
Orange
Grigio
Grey
Giallo
Yellow
X2
X21
Valvola di zona o
Remotazione
pompa supple-
allarme
mentare
Alarm remote
Zone valve or
control
additional pump
X25
TBT: Termostato bassa
temperatura
TBT: Low temperature
limit thermostat