ESAB A2 PEK Instruction Manual page 18

Hide thumbs Also See for A2 PEK:
Table of Contents

Advertisement

GB
3.1
Settings for submerged arc welding
Settings
1)
Arc voltage
1)
Welding current
(CA)
1)
Wire feed speed
(CW)
1)
Constant current
(CC)
1)
Cold wire feed speed
1)
Cold wire start delay
(CW)
Travel speed*
Welding direction
AC frequency
AC balance
AC offset
2)
Start data
Flux pre-flow
Start type
Wire creep start
Wire creep start speed
Start phases
Open-circuit voltage
Maximum open-circuit voltage
2)
Stop data
Flux post-flow
Crater filling
Crater filling time
Burnback time
Stop phases
Control parameters
Dynamics
Inductance
Setting limits
Measure limits
1)
The setting range is dependent on the product used.
2)
The menu shows the settings that belong to the selected regulation type.
bi24d1ea
Setting range
14 - 50 V
0 - 3200 A
0 - 2500 cm/min
0 - 3200 A
(CW)
0 - 2500 cm/min
0 - 99,0 s
0 - 200 cm/min
Y - J
10 - 100 Hz
25 - 75%
-300 - +300 A/-10 - +10V
0 - 99.0 s
Direct or Scrape
Auto or Set speed
0 - 1000 cm/min
OFF or ON
OFF or ON
5 - 60 V
0 - 99.0 s
OFF or ON
0 - 10 s
0 - 10 s
OFF or ON
Auto or Set values
Auto or Set values
-
-
In steps of
0.1 V (1V)
1 A
1 cm/min
1 A
1 cm/min
0,1 s
1 cm/min
-
1
1
1 A / 0.1 V
0.1 s
-
-
1 cm/min
-
-
0.1 V
0.1 s
-
0.01 s
0.01 s
-
-
-
-
-
-
- 18 -
Value after
resetting
30 V
400 A
300 cm/min
400 A
300 cm/min
2,5 s
50 cm/min
J
50 Hz
50%
0
0 s
Direct
Auto
20 cm/min
OFF
OFF
50 V
0 s
OFF
1 s
1 s
OFF
Auto
Auto
-
-
© ESAB AB 2009

Advertisement

Table of Contents
loading

This manual is also suitable for:

A6 pek

Table of Contents