00. CONTENT 01. SAFETY INSTRUCTIONS INDEX ATENTION: 01. SAFETY INSTRUCTIONS This product is certified in accordance with European Community (EC) safety standards. 02. AUTOMATISM This product complies with Directive 2011/65/EU of the TECHNICAL CHARACTERISTICS European Parliament and of the Council, of 8 June 2011, on COMPONENTS FLASHING LIGHT the restriction of the use of certain hazardous substances...
Page 3
01. SAFETY INSTRUCTIONS GENERAL WARNINGS WARNINGS FOR TECHNICIANS • This manual contains very important safety and usage information. Read all instructions carefully before beginning the installation/ • Before beginning the installation procedures, make sure that you have usage procedures and keep this manual in a safe place that it can be all the devices and materials necessary to complete the installation consulted whenever necessary.
Page 4
01. SAFETY INSTRUCTIONS RESPONSABILITY • Disconnect means, such as a switch or circuit breaker on the electrical panel, must be provided on the product’s fixed power supply leads in • Supplier disclaims any liability if: accordance with the installation rules. •...
02. AUTOMATISM 02. AUTOMATISM TECHNICAL CHARACTERISTICS COMPONENTS SIGMA X is an electromechanical barrier designed to control vehicle access to private, • Control board • Built-in industrial or commercial areas. inside flashing light Automatism technical specifications: • MF30 Photocells • Power 150W •...
02. AUTOMATISM 02. AUTOMATISM FLASHING LIGHT MANUAL OPENING / CLOSING This barrier has two RGB flashing light integrated in the top cover, for emission of red, green and blue In an emergency or during the barrier installation / adjustment phase, it may be necessary to move colors.
03. INSTALLATION 03. INSTALLATION REMOVE COVER AND PROFILES FOUNDATION CREATE FOUNDATION This barrier allows free access to the interior to facilitate the product installation and maintenance • process. To do so, remove the aluminum cover and profiles from the barrier. Drill a hole of 355x470mm and 400mm (or greater) deep to create the fixing foundation.
7B (not supplied in the kit). *Once fixed at the ground, the SIGMA X is ready to allow a position adjustment of a few millimeters. Adjustment is made by rotating the barrier in relation to its center.
If you order the SIGMA X without specifying the position of the boom, it will be mounted on the If you order the SIGMA X for a 6 meter boom (SIGMA - X6) it will be mounted with 2 springs.
03. INSTALLATION EXCHANGE 2 SPRINGS FOR 1 SPRING If the springs are on the wrong side for the desired boom direction (see diagram on page 9A), the position of the springs on the rotation lever must be reversed. To do this, you will need to: 1 ·...
03. INSTALLATION BOOM MOUNTING Fit the remaining pieces in the order shown in the picture. Route the cable that comes out of the barrier shaft through the hole REVERSE BOOM SUPPORT • in the assembly you assembled. Secure the parts to the boom clamping plate with screws and bolts provided in the package.
03. INSTALLATION FIX BOOM SUPPORTS SET EXTENDABLE BOOM LENGTH ADJUSTING SUPPORT (FIXED) HEIGHT • • If the height of the support arm is misaligned to the height of the boom you will have to adjust the arm You should now set its length so that you can then place the support as shown in the image below. height.
03. INSTALLATION ADJUST THE SPRINGS Before adjusting the springs, manually place the boom in a vertical position so that the springs are in Hold the threaded rod with pliers so that it does the lowest tension position (see page 5B). not rotate, and then tighten the adjusting nut until each spring is stretched the distance mentioned in the table on page 14.
03. INSTALLATION 03. INSTALLATION TESTING SPRING ADJUSTMENT POWER CABLE * The barrier structure has a tube located on the inside so that it can lead the supply wiring to the connectors The motor must remain unlocked to perform the tuning test. (top of the barrier).
03. INSTALLATION 03. INSTALLATION ADJUST STOPPERS FINE-TUNING THE LIMIT SWITCHES The stoppers in the barrier are visible in the image of the ceiling. The SIGMA-X has limit switches to complete the opening and closing maneuvers, located on the • They consist of 2 adjusting screws (one on each side of the barrier) fastened to the base as well as its rotation lever.
03. INSTALLATION APPLY PROFILES AND COVER APPLY PROFILES • Position the BACK PROFILE in the correct location (profile previously placed for boom application). Holding the BACK PROFILE so that it does not dislocate, fit the SIDE PROFILES into the barrier frame.
05. TROUBLESHOOTING INSTRUCTIONS FOR FINAL CONSUMERS / SPECIALIZED TECHNICIANS Anomaly Procedure Behavior Procedure II Discovering the origin of the problem 1 • Remove the barrier top cover; • Barrier • Make sure you have • Still not working • Consult a qualified 2 •...
Need help?
Do you have a question about the SIGMA X and is the answer not in the manual?
Questions and answers