CONTENT SAFETY INSTRUCTIONS INDEX STANDARDS TO FOLLOW 00. CONTENT ATTENTION: Index | page 01.A To ensure the safety of people, it is important that you read all the following 01. SAFETY INSTRUCTIONS instructions.Incorrect installation or incorrect use of the product can cause physical Standards to follow | page 01.B injury and material damage.
PACKAGE OPERATOR INSIDE PACKAGE FUNCTIONALITY The operator LINCE, is a product developed exclusively for the automatic opening of In the package you will find the following components: swing gates. 02 Swing operators LINCE Besides being pratical, safe and powerful, this product has a new function incorpo- 01 Control Board rated so that you can transform a motor to apply on right leaves to left leaves.
Page 4
OPERATOR OPERATOR FUNCTIONALITY MANUAL RELEASE 03 - Loosen the screws of the Middle Part 04 - Remove Middle Part 01 - Remove the plastic cap from the rear Information engraved on the unlock shaft D=Unlock || B= Lock 05 - Rotate Upper Part 180° 06 - Assemble operator by tightening all 02 - Insert Release key on the unlock 03 - Rotate key 180 °...
3000mm 4000mm LINCE 400 || 600 dimensions are the following: Dimension A - Vertical distance from the floor to the top of the rear support . Dimension B - Vertical distance from the floor to the top of the front support.
Page 6
INSTALATION INSTALATION HORIZONTAL INSTALATION DIMENSIONS HORIZONTAL INSTALATION DIMENSIONS On the Illustrated diagrams below and on the next page, are the horizontal dimensions for the installation of the automated system. INTERIOR OPENING EXTERIOR OPENING Axis of rotation of the Opening mechanical stopper motor, on the front (EXTERIOR) bracket...
INSTALATION INSTALATION INSTALLATION STEPS INSTALLATION STEPS 04 - Install operator on the supports Pay attention to installation dimensions mentioned on pages 04.B, 05.A and 05.B! The operator must be placed on both supports the same time to avoid leaving the operator suspended by only one of 01 - Fixing rear support the supports.
INSTALATION INSTALLATION MAP EXTERIOR PHOTOCELLS LINCE OPERATOR KEY SELECTOR WARNING LAMP ANTENNA CONTROL BOARD JUNCTION BOX EXTERIOR PHOTOCELLS LEGEND: Connection cables It is important to use mechanical stoppers in the opening and closing position It is important to use junction boxes for connections between motors, of the gate.
TROUBLESHOOTING FINAL CONSUMERS INSTRUCTIONS INSTRUCTIONS FOR SPECIALIZED INSTALLERS Anomaly Procedure Procedure II Discovering the origin of the problem Behavior Motor Make sure you Still not Consult a qualified Open control box and check if Disconnect motors from If the motors work, the 5 If the motors doesn’t work, doesn't work have 230V power...
COMPONENTS TEST MAINTENANCE CAPACITORS CONNECTION SCHEME MAINTENANCE To detect which components have problems on an automated system, sometimes it is Clean stainless steel arm necessary to conduct tests using a direct connection to a 230V AC power supply. For this it is necessary to merge a 8µF capacitor to make the operator to work. With a cloth soaked in lubricant spray, In the diagram below is shown how this link should be made and how to merge the wipe any residue that accumulates on...
Need help?
Do you have a question about the LINCE 400 and is the answer not in the manual?
Questions and answers
Posso cambiare il motore lince 400 **** un altro motore simile