2. Specifications

2.1 Electrical Specifications

Parameters
Output Current (peak)
Operating Voltage
Logic signal current
Pulse input frequency
(5V @ 50% dutycycle)
Pulse input frequency
(24V @ 50% dutycycle)
Minimal pulse width
Minimal direction setup
Isolation resistance

2.2 Environment

Cooling
Operating Environment
Storage Temperature
Weight
Min
Typical
0.5
20
24, 36, 48
7
0
0
1μS @ 5V,
or 2.5μS @ 24V
5.0
100
Natural Cooling or Forced Cooling
Environment
Humidity
Operating Temperature
Vibration
-20°C - 65°C (-4°F - 149°F)
CS-D507E Closed Loop Stepper Drive User Manual
Max
-
7.0
50
10
16
-
500
-
200
-
-
-
-
Avoid dust, oil fog and corrosive gases
40%RH-90%RH
0°C - 40°C (32°F - 104°F)
10-50Hz / 0.15mm
Approx. 280 g (9.9 Oz)
Unit
A
VDC
mA
kHz
KHz
μS
μS