Factory Reset

4
Factory Reset
Anybus Wireless Bolt can be reset to the factory default settings using either of
the following methods:
Press and hold the Reset Button for >10 seconds and then release it
Execute Easy Config Mode 2 through the web interface
Issue the AT command AT&F

Factory Default Settings

Network Settings
IP Assignment
IP Address
Subnet Mask
Default Gateway
WLAN Settings
Operating Mode
Channel Bands
Authentication Mode
Channel
Bluetooth Settings
Operating Mode
Local Name
Security Mode
System Settings
Password
Anybus
®
Wireless Bolt
Setting a secure password for the unit is strongly recommended.
Installation Guide
Static
192.168.0.99
255.255.255.0
192.168.0.99
Client
2.4 GHz & 5 GHz
Open
Auto
PANU (Client)
[generated from MAC address]
Disabled
[empty]
10 (16)
SCM-1202-006/SP2139 1.7