Function list

Communication-related function list (Application)
Category
Subcategory Functions
Network
Open network
Common
protocol
Profile
Application
Cyclic
function
transmission
Setting change

Communication specifications

CC-Link IE Field Network Basic communication
Item
Communication protocol
Physical layer
Communication connector
Communication cable
Network topology
Communication speed
Transmission distance between stations
Number of connection nodes
Cyclic transmission
Port number
IP address
Subnet mask
Message format
Reference response time
(Link scan time/timeout time
*1 The reference response time is the time it takes for the servo amplifier to receive a command from the master station and respond to the
master station.
*2 The link scan time is calculated by the following formula. Use the reference response time for Ns.
For MELSEC iQ-R/MELSEC-Q/L: Ls = Ns + Nm
For MELSEC iQ-F: Ls = SM + {(Ns + Nm)/SM}
Ls: Link scan time, Ns: Remote station response time, Nm: Master station request time, SM: Sequence scan time
*3 Check the current link scan time (when all remote stations are normal) with CC-Link IE Field Network Basic diagnostics, and set the
timeout time to about 5 times the link scan time (50 ms if the current link scan time is 10 ms).
2 CC-Link IE Field Network Basic
80
2.1 Functions and configuration
CC-Link IE Field Network
Basic protocol
CC-Link IE Field Network
Basic communication
settings
SLMP
CSP+
Hold/Clear of output at
CPU STOP and CPU
stop error
Remote reset
IP address setting
Description
UDP
100BASE-TX (100 Mbps/100 m)
RJ-45 × 2
CAT5e, shielded twisted pair, shield twisted 4 pair, straight cable
Line, tree, star, or hybrid of these three topology types
100 Mbps
Max. 100 m
Maximum 64 stations (Maximum number of connected stations per group: 16 stations)
MR-J5-_G_, MR-J5D1-_G_ (Number of usable stations: 1 station per MR-J5-_G_/MR-J5D1-_G_)
32 points (64 bytes)
61450 (cyclic data)
61451 (NodeSearch, IPAddressSet for CC-Link IE Field Network Basic)
IPv4 range: 0.0.0.1 to 223.255.255.254
Use the same network address for the master station and remote station.
Network address default value (recommended): 192.168.3.1
Subnet mask default value (recommended): 255.255.255.0
Page 89 Message format
*1
10 ms
*2*3
)
Description
This function supports CC-Link IE Field Network Basic.
Network configuration settings are performed by using GX Works2,
GX Works3, and MR Configurator2.
This function supports SLMP (SeamLess Message Protocol).
Parameter settings and monitoring are available.
File for describing the necessary information for startup, operation,
and maintenance of CC-Link family connected products.
When the CPU module of the cyclic master is at STOP, when the
stop error occurs, Hold/Clear is automatically set on the refresh
device output. The servo amplifier stops regardless of the setting of
Hold/Clear of the cyclic master.
This is a function to reset a servo amplifier via the network. Servo
parameters to be enabled at power cycle are reflected by resetting
the servo amplifier.
IP addresses are delivered from the controller to servo amplifiers
via CC-Link IE Field Network Basic.
Detailed explanation
Page 89 Cyclic
transmission
Page 84 Startup
Page 105 SLMP
Page 85 Profile
(CSP+ file) settings
Page 88 Hold/Clear
of output at CPU STOP
and at CPU stop error
Page 88 Remote
reset
Page 87 IP address
setting function

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5w-g

Table of Contents