How to Calibrate the Temperature Probe

Before you begin
Procedure
Con v er ge®
Ope rato r's M an ual
Make sure:
The oven is on, but not in cooking or holding mode.
You have a thermometer.
You have a container filled with ice and water.
To calibrate the probe, do the following.
Step
Action
1.
Place the probe and the thermometer in a container of ice water and allow
the temperature to settle to 32°F (0°C).
2.
Touch
the menu icon
a
3.
Touch
the "Settings" icon
M N-472 38
Re v 1
8/22
a
. The menu screen displays.
b
. The "General Settings" screen displays.
b
O
PERATION
CT-TS-014846
CT-TS-014849
Continued on next page