Alto-Shaam 6•10 Installation Manual

Alto-Shaam 6•10 Installation Manual

Es electric combiclean combination oven / steamer
Hide thumbs Also See for 6•10:

Advertisement

W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA
PHONE:
262.251.3800 • 800.558.8744
.
.
.
p r i n t e d i n u
s
a
Oven / Steamer
/
usa
caNada
.
-
.
www
altO
sHaaM
cOM
C o m b i t h e r m
C o m b i n a t i o n
ES ElECtriC
6•10
10•10
7•14
10•18
12•20
20•20
VHes-5
VHes-10
• InstallatIon
FaX:
262.251.7067 • 800.329.8744
®
.
.
.
u
s
a
ONly
M N - 2 8 8 9 7 • 0 2 / 1 2

Advertisement

Table of Contents
loading

Summary of Contents for Alto-Shaam 6•10

  • Page 1 C o m b i t h e r m ® C o m b i n a t i o n Oven / Steamer ES ElECtriC 6•10 10•10 7•14 10•18 12•20 20•20 VHes-5 VHes-10 • InstallatIon W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA PHONE: 262.251.3800 •...
  • Page 2: Table Of Contents

    Delivery Electrical Connection Unpacking Motor Rotation Safety Procedures and Precautions Mobile Equipment Restraint Water Quality Requirement Installation Water Connections Site Requirements Water Drainage Ventilation Requirements Installation Checklist Positioning on Site Control Reset Lifting Instructions Error Codes Leveling Ventless Hood Option Stand Installation Accessories Condensate Drain...
  • Page 3: Delivery

    Tech Team service manuals are available from the alto-shaam department if you have any questions concerning tech team service department.
  • Page 4: Safety Procedures And Precautions

    safety procedures and precautions Knowledge of proper procedures is essential to the 1. This appliance is intended to cook, hold safe operation of electrically and/or gas energized or process foods for the purpose of human equipment. in accordance with generally accepted consumption.
  • Page 5: Installation

    i n s t a l l a t i o n s i t e i n s t a l l a t i o n d a n g e r d a n g e r IMPROPER INSTALLATION, AVERTISSEMENT : UNE INSTALLATION, ALTERATION, ADJUSTMENT,...
  • Page 6: Positioning On Site

    i n s t a l l a t i o n s i t e i n s t a l l a t i o n c a u t i o n ® THE APPLIANCE MUST REMAIN ON THE PALLET WHILE BEING MOVED TO THE INSTALLATION SITE BY FORK LIFT OR PALLET LIFT TRUCK.
  • Page 7: Lifting Instructions

    i n s t a l l a t i o n s i t e i n s t a l l a t i o n Lifting Instructions Remove banding before lifting. Place a spacer board(s) 24” in Front View length, with a minimum height of 1-1/2”...
  • Page 8: Leveling

    i n s t a l l a t i o n s i t e i n s t a l l a t i o n positioning requirements q in order to ensure proper ventilation, a minimum distance of at least 6-inches (152mm) must be kept from the control panels side (left) of the oven and any adjoining surfaces.
  • Page 9: Accessories

    i n s t a l l a t i o n a c c e s s o r i e s combiclean® Tablets — ce-28892 sPEcially FOrMulatEd FOr cOMbitHErM OvENs , 90 ➥ cONtaiNErs PackEts EacH cONtaiNEr combitherm cleaning liquid — ce-24750 sPEcially FOrMulatEd FOr cOMbitHErM OvENs (12)
  • Page 10: Specifications, 6•10Es

    17-3/4" x 23-1/2" x 21-1/16" (450mm x 597mm x 535mm) water requirements water quality minimum standards TWO (2) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. * can manifold off of ONE (1) TREATED WATER INLET: 3/4"...
  • Page 11: Specifications, 6•10Esi

    17-3/4" x 23-1/2" x 21-1/16" (450mm x 597mm x 535mm) water requirements water quality minimum standards using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM TWO (2) COLD WATER INLETS - DRINKING QUALITY waTer QualiTy sTandards will Void This warranTy. 3/4" npT*...
  • Page 12: Specifications, 6•10Esin

    17-3/4" x 13-1/4" x 26-1/4" (450mm x 387mm x 665mm) water requirements water quality minimum standards TWO (2) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. * can manifold off of ONE (1) TREATED WATER INLET: 3/4"...
  • Page 13: Specifications, 10•10Es

    27" x 23-1/2" x 21-1/16" (685mm x 597mm x 535mm) water requirements water quality minimum standards using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM TWO (2) COLD WATER INLETS - DRINKING QUALITY waTer QualiTy sTandards will Void This warranTy. 3/4" npT*...
  • Page 14: Specifications, 10•10Esi

    27" x 23-1/2" x 21-1/16" (685mm x 597mm x 535mm) water requirements water quality minimum standards TWO (2) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. * can manifold off of ONE (1) TREATED WATER INLET: 3/4"...
  • Page 15: Specifications, 10•10Esin

    27" x 13-1/4" x 26-1/4" (685mm x 387mm x 665mm) water requirements water quality minimum standards using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM TWO (2) COLD WATER INLETS - DRINKING QUALITY waTer QualiTy sTandards will Void This warranTy. 3/4" npT*...
  • Page 16: Specifications, 7•14Es

    20-5/16" x 23-1/2" x 28-7/8" (515mm x 596mm x 722mm) water requirements water quality minimum standards TWO (2) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. * can manifold off of ONE (1) TREATED WATER INLET: 3/4"...
  • Page 17: Specifications, 7•14Esi

    20-5/16" x 23-1/2" x 28-7/8" (515mm x 596mm x 722mm) water requirements water quality minimum standards TWO (2) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM * can manifold off of waTer QualiTy sTandards will Void This warranTy. ONE (1) TREATED WATER INLET: 3/4"...
  • Page 18: Specifications, 10•18Es

    30-3/4" x 23-1/2" x 28-7/16" (781mm x 596mm x 722mm) water requirements water quality minimum standards TWO (2) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. * can manifold off of ONE (1) TREATED WATER INLET: 3/4"...
  • Page 19: Specifications, 10•18Esi

    30-3/4" x 23-1/2" x 28-7/16" (781mm x 596mm x 722mm) water requirements water quality minimum standards TWO (2) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. ONE (1) TREATED WATER INLET: 3/4" npT* * can manifold off of one 3/4"...
  • Page 20: Specifications, 12•20Es

    38-11/16" x 26-1/4" x 32-11/16" (983mm x 667mm x 830mm) water requirements water quality minimum standards TWO (2) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. 3/4" npT* ONE (1) TREATED WATER INLET: * can manifold off of one 3/4"...
  • Page 21: Specifications, 12•20Esi

    38-11/16" x 26-1/4" x 32-11/16" (983mm x 667mm x 830mm) water requirements water quality minimum standards TWO (2) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. 3/4" npT* ONE (1) TREATED WATER INLET: * can manifold off of one 3/4"...
  • Page 22: Specifications, 20•20Es

    60-1/4" x 26-1/4" x 32-11/16" (1530mm x 667mm x 830mm) water requirements water quality minimum standards TWO (2) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. 3/4" npT* ONE (1) TREATED WATER INLET: * can manifold off of one 3/4"...
  • Page 23: Specifications, 20•20Esi

    60-1/4" x 26-1/4" x 32-11/16" (1530mm x 667mm x 830mm) water requirements water quality minimum standards TWO (2) COLD WATER INLETS - DRINKING QUALITY using a waTer supply noT MeeTing alTo-shaaM’s MiniMuM waTer QualiTy sTandards will Void This warranTy. ONE (1) TREATED WATER INLET: 3/4" npT* * can manifold off of one 3/4"...
  • Page 24: Electrical Connection

    i n s t a l l a t i o n e l e c t r i c a l c o n n e c t i o n d a n g e r d a n g e r ENSURE POWER SOURCE To avoid electrical shock, this appliance MUST be adequately...
  • Page 25 i n s t a l l a t i o n e l e c t r i c a l c o n n e c t i o n d a n g e r d a n g e r To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local...
  • Page 26: Motor Rotation

    i n s t a l l a t i o n e l e c t r i c a l c o n n e c t i o n motor with rotation direction electrical connection terminal block ground electrical panel d a n g e r...
  • Page 27: Mobile Equipment Restraint

    i n s t a l l a t i o n m o b i l e e q u i p m e n t r e s t r a i n t any appliance that is not furnished with a a mounting connector for a restraining device is power supply cord but includes a set of casters located on the lower back flange of the appliance...
  • Page 28: Water Quality Requirement

    equipment.
  • Page 29: Water Connections

    CombiGuard™ note: FI-23014 shown both treated and untreated water connections must alto-shaam now offers an improved water be connected For ProPer filtration system for combitherm . The ® oPeration oF the oven. combiguard™ 10 & 20 triple-guard water...
  • Page 30: Water Drainage

    i n s t a l l a t i o n w a t e r v a l v e s h u t o f f v a l v e s h o w n i n t h e o f f p o s i t i o n note: the shut-oFF valve must be in the oPen Position...
  • Page 31: Installation Checklist

    Verify 1/8" (3.2mm) pitch to 10' (305cm) of drain line. sTore has seen This iMporTanT: Alto-Shaam has listed Water Quality Requirements in the recoMMendaTion: installation manual for this equipment. It is the responsibility of the end...
  • Page 32: Control Reset

    i n s t a l l a t i o n CO NTR O L RES ET There is a remote possibility in the day-to-day operation of the Combitherm that the control could lock or freeze. If this occurs, the control is easy to reset. PRESS AND HOLD THE POWER KEY FOR A PERIOD OF 5 SECONDS.
  • Page 33 i n s t a l l a t i o n ERROR CODES AND REASONS (continued) Error Display Shows When does the error occur? Possible reason Code ES units only: Excess Steam Gen Temp • Problem with water level probe. Activated if the temperature of the steam •...
  • Page 34 i n s t a l l a t i o n ERROR CODES AND REASONS (continued) Error Display Shows When does the error occur? Possible reason Code Probe Short to Frame Activated if one or more of the temperature •...
  • Page 35 i n s t a l l a t i o n E m E R g E N C y O P E R A T i O N In the event of an error code, the Combitherm may be operated on a limited basis. Error conditions under which continued operation can be conducted are indicated by “Yes”...
  • Page 36: Filter Door Latch

    The Ventless hood option is factory installed directly on the top of the alto-shaam combitherm oven. The hood is designed to vent clean air back into the kitchen, filtering vapors and grease.
  • Page 37: Operation

    i n s t a l l a t i o n v e n t l e s s h o o d o p t i o n t o p e x ha us t vent op e r at i on 1 Turn the ventless hood power knob “ON”.
  • Page 38: Original Equipment Limited Warranty

    PRODUCT, OR FOR ANY INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. No person except an officer of Alto-Shaam, Inc. is authorized to modify this warranty or to incur on behalf of Alto-Shaam any other obligation or liability in connection with Alto-Shaam equipment.
  • Page 39: Transportation Damage And Claims

    F.o.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee.

Table of Contents