Setting(Others): Error And Temperature Indications - Mitsubishi Electric KD Series User Manual

Contact image sensor (cis)
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

Address
Register name
DeviceTemperature
7224
Mainboard
DeviceTemperature
7228
Ifboard
7230 DeviceError
5-2-19 Error and temperature indications
[Function]
This function enables to provide some indications of errors,
when cooling fan is stopped or operates at slow speed or a
temperature of internal FPGA becomes abnormally high.
Additionally, this function can provide an information of the
temperature of the internal FPGA.
TM-XH719C

5-2 Setting(others): Error and temperature indications

R/W
Val
R
-
R
-
R
0 to 7
COPYRIGHT©2017-2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
Indicate an internal temperature (℃) of FPGA on Image
processing board (When using multiple image processing
boards, this function indicates the maximum value.)
Indicate an internal temperature (℃) of FPGA on I/F board.
(When using multiple image processing boards, this function
indicates the maximum value.)
Return "Error" indications about cooling fan and FPGA
temperature.
0:Operating normally
'1' at 0bit: Error of cooling fan.
'1' at 1bit: Abnormal temperature of FPGA on Image processing board
'1' at 2bit: Abnormal temperature of FPGA on I/F board
[Remark]
1) When you read the registers, this product returns a
value which shows the internal status of this product.
Please confirm by reading the registers if there is an
error or not. (On your control software attached with
your frame grabber, the software indicates the last
value you operated "read". This value will not be
updated until you will operate "read" again.
Result
Initial
-
-
-
90

Advertisement

Table of Contents
loading