Setting②: Initial Setting Select - Mitsubishi Electric KD Series User Manual

Contact image sensor (cis)
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

Address
Register name
7248 UserSet_Use_600dpi
724C UserSet_Use_300dpi
7250 UserSet_Use_200dpi
7254 UserSet_Use_150dpi
5-2-3 Initial Setting Select-2
[Function]
Save and read CIS correction data when changing resolution
If changing the resolution, please execute this command prior to
save white/dark correction data to flash memory in CIS.
When saving correction data if changing the resolution, please
send this command to suitable address (resolution you want to
use) and changing the value (Parameter Data=1:Activate) prior
to execute UserSet_#_Save.
Correction data for 600dpi can be saved in initial setting.
※ Dark/White correction data is hold in this product every
resolution. However saving and reading action from/to flash
memory in CIS is valid only the resolution which is enabled by
this command.
TM-XH719C
5-2 Setting②: Initial setting select 2
(For products with DeviceFirmwareVersion 2. *. *. *)
R/W
Parameter
Data
R/W
0 to 1
R/W
0 to 1
R/W
0 to 1
R/W
0 to 1
COPYRIGHT©2017-2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
Correction data for 600dpi resolution
0: Disable / 1:Enable
Correction data for 300dpi resolution
0: Disable / 1:Enable
Correction data for 200dpi resolution
0: Disable / 1:Enable
Correction data for 150dpi resolution
0: Disable / 1:Enable
[Remark]
1) Due to all correction data is saved / read, the startup is
slow, therefore it is recommended to set the unused
resolution setting to "Parameter Data=0".
2) When executing UserSet_#_Save, the correction data
of the resolution set to disable is reset.
3) The setting of this command is also valid after turn off
CIS and correction data is reflected when turn on CIS.
Function
Initial
1
0
0
0
74

Advertisement

Table of Contents
loading

Table of Contents