3-3-2 DC5V / DC24Vcable connection
(This cable is not included in the CIS product)
1)Connect ① DC5V power cable to CIS connectors V1/V3.
* On use of the optional PSU, connect ⑩CIS-Optional PSU
cable DC5V.
Type
Power for
CIS (+5V)
2)Connect ② DC24V power cable to CIS connectors V2/V4.
* On use of the optional PSU, connect ⑪CIS-Optional PSU
cable DC24V.
Type
Power for
LED (+24V)
TM-XH719C
3-3 Connections
V3
Model
No.
L1
L2
L3
V1
V3
×
V4
Model (CX series)
No.
L1
L2
V2
V4
×
COPYRIGHT©2017-2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
3) Fix CIS connectors and the cable by screws
CIS has locknut D20418-J3R (JAE) (M2.6, female).
Use M2.6 screw, M2.5 screw, M2.6 type JAE Lock screw,
etc., which are applicable to fix cable connectors.
Recommended screwing torque is 16 - 20 N*cm.
【Remarks】
1) Do not screw with higher torque than recommended.
Otherwise, locknut on CIS may be loosened or removed
when you remove screws.
2) CIS does not support hot-swap.
Make sure to power off CIS before connecting / removing
cables. If the cables are connected / removed while
powered on, it may cause failure on CIS.
3) 24V power ON/Off shall be controlled while 5V power is
ON. Refer to startup sequence in Chapter 4 for further
details.