5-1 Initial settings

5-1-1 Initial settings
Items
Pixel clock frequency
Output format
Resolution
Sync. Signal mode
Dark correction
illumination mode
※ MX-NL series output
the illumination emission
sync. trigger signal
externally
White correction
PGA
Pixel Interpolation
Pixel Overlap
γ correction
TM-XG537C
Initial setting
84MHz
10bit Base Configuration,
Serial, 2 Tap
600dpi
External Sync. Mode
None
Turn On
Both side illumination
Illumination period :15us
None
None (gain = 1.0)
None
None
None
COPYRIGHT © 2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
【 CIS initial settings 】
1)
Initial settings of this product is described on the left
table.
2)
The initial status of this product immediately after
Power-ON is in below.
・ CIS data output :
CIS data output starts after inputting external
synchronization signal. Image data starts to be valid
10 lines after synchronization signal.
・ Illumination (LED)
After Power-ON, the illumination remains to be
turned OFF. After inputting external synchronization
signal, the illumination starts to be turning ON.
3)
For more detailed settings for your application, refer
to each setting , see next pages.
: