Dump Collection; Updating Bmc Firmware - NEC N8800-184F Maintenance Manual

Table of Contents

Advertisement

Chapter 1 Maintenance

4.3.6 Dump collection

If you want to collect the dump during system boot, use the following command. The following command
example generates a dump of the CPU module 0. The system must be running in duplex mode for you to use
this method.
# /opt/ft/bin/ftsmaint dump 0
Generated dump of the device at path 0.
In the result, the dump for the ESXi host is saved in /var/core/vmkernel-zdump-MMDDYY.HH:mm.n on the
ESXi host.

4.3.7 Updating BMC firmware

Use the following command to update the BMC firmware.
# /opt/ft/bin/ftsmaint burnBmcs fw_file
1. Login to ftSys Management Appliance as a root user.
2. Use the SCP command or vSphere Client to store the BMC firmware file in the desired directory of ftSys
Management Appliance.
In the example below, ft control software Install DVD is mounted and BMC firmware file is copied to ftSys
Management Appliance.
# cp /mnt/cdrom/firmware/bmc/2700_4700_6400/062-01210bmc_Bnn.nnRnn.nnP
nn.nnSnn.nn.bin /opt/ft/firmware/bmc/2700_4700_6400
3. Run the following command to check the State shows "ONLINE" and Op State shows "DUPLEX" for I/O
modules 0 and 1.
# /opt/ft/bin/ftsmaint ls 10
H/W Path
...
State
Op State
...
# /opt/ft/bin/ftsmaint ls 11
H/W Path
...
State
Op State
...
Important
Shutdown the guest OS except for ftSys Management Appliance.
Tips
See Chapter 2 (1.1.2 Installing NEC ESMPRO Agent) in Installation Guide for how to
mount/unmount ft control software Install DVD.
: 10
: ONLINE
: DUPLEX
: 11
: ONLINE
: DUPLEX
Express5800/R320d-E4, R320d-M4 Maintenance Guide (VMware 5.5)
4. Maintenance of Express5800/ft series
37