16. Secure the heat sink with four screws.
17. Install the air duct referring to Chapter 2 (5.5.1 Installing DIMM).
18. Refer to Chapter 2 (5.4.2 Installing CPU/IO Module) and install the CPU/IO module.
19. Connect the power cords.
20. Press the POWER switch to power on the server.
21. Verify that POST displays no error message.
If POST displays an error message, write it down and see the POST error message list in Chapter 1
(6.2 POST Error Message).

5.6.2 Removing CPU

Remove the heat sink and CPU in the reverse procedure of installation.
140
Important
Tentatively secure the screws diagonally with the order as shown in the figure
below, check that the heat sink is attached to the CPU socket in parallel, then tighten
the screws diagonally.