Preparing Your System For Upgrade - NEC N8800-184F Maintenance Manual

Table of Contents

Advertisement

Chapter 2 Configuring and Upgrading the System

5.1.4 Preparing your system for upgrade

Note the following, when installing or replacing devices, to improve the performance of Express5800/ft series.
With the Express5800/ft series, devices can be replaced during the continuous operation.
Take extreme care for electric shock and damage to the component due to short-circuit.
Optional devices cannot be installed or removed during continuous operation.
After shutting down OS, check that the server is powered off, disconnect all power cords and interface
cables from the server before installing or removing the optional devices.
To remove the CPU/IO module during the continuous operation, disable the intended module (place the
module off-line) by using the ftsmaint command.After a new module is installed to the server, enable the
module using the ftsmaint command.
Make sure to provide the same hardware configuration on both CPU/IO modules
Use the same slots and sockets on both groups.
Do not install those devices having different specifications, performance, or features.
Before removing the set screws from the CPU/IO modules, place the desired module off-line using the
ftsmaint command.
Tips
The system is defaulted to automatically boot the module, once installed.
Express5800/R320d-E4, R320d-M4 Maintenance Guide (VMware 5.5)
5. Installing Optional Devices
113

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/r320d-m4Express5800/r320d-e4N8800-185f

Table of Contents