P0-10
GM .998L Engine Maintenance – Under 1000 Hours
Additional engine maintenance is required. Refer to the Programmed Maintenance Inspection Report for
the specific intervals that apply.
Required maintenance procedures and additional engine information are available in the manufacturer's
manuals. Refer to Specifications, Engine Operator and Maintenance Manuals.
GM .998L Engine
Procedure
Coolant level - check
Oil level - check
Oil, fuel and coolant systems - check for leaks
Fan belt tension and damage - check
Radiator hoses and clamps - check
Intake manifold - check for vacuum leaks
LPG system - check for leaks
Radiator – clean • Radiator hoses and clamps - check
Engine oil and filter – replace
LPG Vaporizer - drain/clean
PCV valve - check
Air cleaner element - clean/replace
Timing belt - check
Electrical wiring - check for chafing or damage
Vacuum lines and fittings - check
Fuel filter - replace
Fuel lines and clamps - check for leaks
Air intake system - inspect for leaks
Cylinder head bolts - torque (40.5 ft-lbs / 55 Nm)
Valve clearance - check/adjust
PCV valve - replace
Cooling system coolant - replace
Spark plugs - replace
Spark plug wires - check/replace
138
Daily
∅ = Not required
S
®
Booms • Z
®
Booms
Hour Intervals
100
150
200
Part No. 1268489GT
April 2018
400
800