JUKI PS-900-13090 Instruction Manual page 72

Table of Contents

Advertisement

Error
Error description
Code
E065 Main shaft locked rotor
E066 Main shaft detection for
locked rotor
E067 Y servo hardware protec-
tion
E068 Y servo HOC
E069 Y axis AD sampling module
failure
E070 Y servo parameter storage
exception
E071 Y servo system parameter
is abnormal
E072 Y axis AD sampling module
failure
E073 Y servo encoder discon-
nected
E074 Y servo encoder AB inter-
ference
E075 Y servo encoder Z interfer-
ence
E076 Y servo bus undervoltage
E077 Y servo software over cur-
rent
E078 Y servo motor overload
E079 Y servo motor overload
E080 Y servo driver overload
E081 Y servo motor overheated
E082 Y servo drive overheated
E083 Y servo fan is abnormal
Fault Cause
1. The load is too heavy
2. The main shaft is mechanically
stuck
The main shaft load is too large
1. The motor is broken or the motor
wire is broken and short circuited
2. The motor is stuck
3. Y servo board is broken
4. The parameters are incorrect
1. Abnormal startup
2. The motherboard is damaged
Abnormal memory chip
Parameter configuration error
1. Abnormal startup
2. The motherboard is damaged
1. Y servo encoder has poor contact
or disconnection
2. Y servo motor is broken
3. Y servo board is broken
1. The Y servo board program is the
old version
2. Poor contact or broken wire of the
servo encoder
1. The Y servo board program is the
old version
2. Poor contact or broken wire of the
servo encoder
1. Voltage drop
2. The bus load is too heavy
3. Transformer failure
1. The parameters are incorrect
2. The motor is stuck
3. The motor is broken or the motor
wire is damaged and short circuit-
ed
4. The power board is damaged
The Y axis is overloaded
Motor overload
– 69 –
Solution
1. Lighten the load
2. Check the machine
Check the main shaft mechanical structure
for problems
1. Check and replace the motor
2. Check the machinery
3. Replace Y servo board
4. Reset or redirect parameters
Spare alarm
1. Restart
2. Replace the motherboard
Replace the chip
Check parameter configuration
1. Restart
2. Replace the motherboard
1. Check the Y servo encoder line
2. Replace Y servo motor
3. Replace Y servo board
1. Look at the screen "Internal Drive" - "Y
"Version Number", 1 means the old ver-
sion needs to be returned to the factory
to update the program
2. Check the encoder cable
1. Look at the screen "Internal Drive" - "Y
"Version Number", 1 means the old ver-
sion needs to be returned to the factory
to update the program
2. Check the encoder cable
1. Increase the voltage
2. Reduced load operation
3. Repair or replace the transformer
Spare alarm
1. Reset or redirect parameters
2. Check the machinery
3. Check and replace the motor
4. Replace the power board
Lighten the load
Refer to
E026
Error Handling Method
Lighten the load
Refer to
E029
Error Handling Method
Spare alarm

Advertisement