Gi29LE LP Conversion
installation
14. Reverse steps 7 to 2.
15. Attach the "This unit has been converted
to LPG" label near or on top of the serial
decal.
16. Replace the yellow "Natural Gas" label with
the red "LPG" label.
17. Adjust the aeration settings - see the "Air
Shutter Adjustment" section in themanual.
18. Start the appliance (see the "Lighting In-
structions" section in the manual). Ensure
that pilot and burner ignition are completed
without delay. Check your inlet and outlet
pressures at full load. With a soapy solution,
leak test the entire system. Verify correct
flame and pilot appearance.
Wires must be secured by gray clips
when reinstalling.