5. Disconnect the green, orange and yellow cables from the valve.
5. Disconnect the green, orange, and yellow cables from the valve
Do not use the ground lug
on top of the valve
Disconnect
6. Slide out IFC tray and disconnect the pilot wires and motor wire.
6. Slide out IFC tray and disconnect the pilot wires and motor wire
Pilot Wires
Motor Wire
Wires must be secured by gray clips
when reinstalling.
7. Disconnect the incoming gas ex line from the ball valve. Slide the pilot wires through the grommet to remove.
7. Disconnect the incoming gas flex line from the ball valve. Slide the pilot
wires through the grommet to remove.
Remove pilot wires
from grommet
8. Remove the remaining 12 screws and lift the valve tray out.
8. Remove the remaining 12 screws and lift the valve tray out
9. Remove the 2 screws from each side of the valve and disconnect pilot gas line to remove valve.
9. Remove the 2 screws from each side of the valve and disconnect pilot
gas line to remove valve.
10. Reverse steps 9-1 to replace with new gas valve assembly.
maintenance
Disconnect gas ex line
Gi29 Direct Vent Gas Insert |