Door Glass; Glass Replacement; General Vent Maintenance; Log Replacement - Regency Fireplace Products Gi29LE Owners & Installation Manual

Gas insert
Table of Contents

Advertisement

maintenance

Door Glass

Your Regency insert is supplied with high
-temperature Neoceram glass that will withstand
the highest heat your unit can produce. If your
glass requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials. Do not clean
the glass when hot.
If you break the door glass, purchase a replacement
from an authorized Regency dealer and follow our
step-by-step instructions for replacement.
• Do not clean when the glass is hot.
• The use of substitute glass will
void all product warranties.
• Take care not to break the glass.
• Do not operate this fireplace
without the glass front, or with
broken glass.
• Wear gloves when removing
damaged or broken glass.
• Replacement of the glass panel(s)
should be done by a qualified
service person.

Glass Replacement

In the event that you break your glass, purchase
your replacement from an authorized Regency
dealer.
Replacement ceramic glass (Part #940-536/P) is
shipped with a gasket.
60
| Gi29 Direct Vent Gas Insert

General Vent Maintenance

Conduct an inspection of the venting system
semiannually. Areas to inspect are as follows:
1. Check the venting system for corrosion in areas
exposed to the elements. Components with
rust spots, streaks, or holes should be replaced
immediately.
2. Remove the termination cap and shine a flash-
light down the vent. Remove any bird nests or
other foreign material.
3. Check for evidence of excessive condensation,
such as water droplets in the inner liner dripping
out the joints. Continuous condensation can
cause corrosion of caps, pipes, and fittings. It
may be caused by excessive lateral runs, too
many elbows, or exposure to cold weather.
4. Inspect joints to verify that no pipe sections or
fittings have been disturbed and consequently
loosened. Also, check mechanical supports such
as wall straps or plumber's tape for rigidity.

Log Replacement

Never use the unit with broken logs. Turn off the
gas valve and allow the unit to cool before carefully
removing the logs. Use the proper replacement log
for any that are broken. Position the logs as shown
in the diagram in the "Log Installation" section of
this manual.
®
• Improper positioning of logs may create
carbon build-up and will alter the unit's
performance which is not covered under
warranty.

Glass Gasket

If the glass gasket requires replacement, use Flush
Front (Part # 936-273). Glass gasket is sold by the
foot; seven feet are required for this installation.