Flue Collar Installation/Removal - Regency Fireplace Products Gi29LE Owners & Installation Manual

Gas insert
Table of Contents

Advertisement

Flue Collar Installation/Removal

1. Detach the flue collar from the unit by removing the screws and sliding
the plate backward.
Connector plate
screws
2. Attach the exhaust and intake flue liners to the flue collar with a minimum
of three self-tapping screws. Use Mil-Pac sealant to seal pipes.
3. Pull the flue collar through the cutout in the top of the insert using the
flue collar tool provided. See diagram 2.
Diagram 2
Ensure the draft hood is properly secured and
screws tight to create proper seal.
Air Intake
Exhaust
4. The tabs on the insert will seal the flue collar against the intake inlet
and exhaust outlet. Secure with the two screws removed in step 1.
5. Tighten the two Phillips screws to secure the collar.