Continuous Pilot/Intermittent Pilot (CPI/IPI)
selection
Note: Power vent models do not have a Continuous
Pilot option.
With the system in "OFF" position press the Mode Key (fig. 1) to index
to the CPI mode icon (fig. 19 & 20).
Pressing the Up Arrow Key will activate the Continuous Pilot Ignition
mode (CPI). Pressing the Down Arrow Key will return to IPI. A single
"beep" will confirm the reception of the command.
Thermostat Icon: If the thermostat icon is not present on the re-
mote transmitter, follow instructions noted below:
1. Remove one battery from the remote.
2. Press and hold down the Thermostat button on the remote.
3. Reinstall the battery(removed in Step 1) while still holding down
thermostat button.
4. If you see "Set" the thermostat option is now enabled. If you see
"Clr" the thermostat option is now disabled.
5. Repeat the procedure if the "Set" or "Clr" to remove or add the
option back to the remote did not appear.
Enable all other functions if not present on the remote transmitter, fol-
low instructions noted below:
1. Remove one battery from remote.
2. Press and hold both the ON/OFF and MODE button at the same
time .
3. Reinstall battery removed in Step 1 while holding both buttons—
keep holding buttons, then release the MODE button only.
4. The screen will show either "Clr" or "Set" as the first option avail-
able is to disable or enable a mode.
5. "Clr" will remove a mode—use the up or down arrow while holding
down ON/OFF and MODE (mode icon will disappear once removed).
6. Use the "MODE" button to move to the next function.
7. "Set" will add a mode —use the up or down arrow while holding down
ON/OFF and MODE (mode icon will appear when added).
8. Use the "MODE" button to move to the next function.
Note: You should never program out the fan (if installed) or CPI/IPI
mode on the remote.
14
| Gi29 Direct Vent Gas Insert
Figure 20
Key Lock
This function will lock the keys to avoid unsupervised operation.
To activate this function, press the MODE and UP Keys at the same
time (fig. 21).
To de-activate this function, press the MODE and UP Keys at the
same time.
Figure 21
Low Battery Power Detection Transmitter
The life span of the remote control batteries depends on various factors:
quality of the batteries used, the number of ignitions of the appliance,
the number of changes to the room thermostat set point, etc.
When the Transmitter batteries are low, a Battery Icon will appear on
the LCD display of the Transmitter (Fig. 22) before all battery power is
lost. When the batteries are replaced this Icon will disappear.
Figure 22