8.3. Unit Components
8.3.1. Optical Carriage /
1. Remove FB Glass Base.
(See 8.2.11.)
2. Remove ADF Glass Base.
(See 8.2.12.)
3. Remove 2 screws(A) and Loosen screws(B) and pull out Shaft, as
shown in Fig.8-24.
4. Disconnect Connector from Optical Carriage.
Note:
When assembling, supply the cable to this carriage so that "CCD"
character is seen from front side.
5. Remove Optical Carriage.
Fig. 8-24