CN1006 (MAIN) - CN2001 (MOTHER)
Pin No.
Signal Name
99
BUZZER
100
LED(RD)
101
LED(GR)
102
*CPURD
103
*CPUHWR
104
*CPUAS
105
GND
106
GND
107
*RESET
108
CPUA0
109
CPUA1
110
CPUA2
111
CPUA3
112
CPUA4
113
CPUA5
114
CPUA6
115
CPUA7
116
CPUA8
117
+5VD
118
CPUD8
119
CPUD9
120
CPUD10
121
CPUD11
122
CPUD12
123
CPUD13
124
CPUD14
125
GND
126
CPUD15
127
*RESET(IMP)
128
*POSTIMP SP
129
CTS1(POST)
130
RTS1(POST)
131
RXD1(POST)
132
TXD1(POST)
133
*PREIMP SP
134
CTS0(PRE)
135
RTS0(PRE)
136
RXD0(PRE)
137
TXD0(PRE)
138
DALD2
139
GND
140
GND
CN602(SCSI) - CN2002(MOTHER)
Pin No.
Signal Name
1
GND
2
GND
3
*RESET
4
+3VD
5
+3VD
6
*CPUAS
7
*CPUHWR
8
*CPURD
9
GND
10
GND
11
CPUD15
12
CPUD14
13
CPUD13
14
CPUD12
15
+5VD
16
+5VD
17
CPUD11
18
CPUD10
19
CPUD9
20
CPUD8
(continued)
Description (S6055)
Buzzer Pulse
LED(Red)
LED(Green)
CPU Read
CPU Write
CPU Address Strobe
Ground
Ground
Reset
CPU Address
CPU Address
CPU Address
CPU Address
CPU Address
CPU Address
CPU Address
CPU Address
CPU Address
+5V(for Digital)
CPU Data
CPU Data
CPU Data
CPU Data
CPU Data
CPU Data
CPU Data
Ground
CPU Data
Reset(for Imprinter)
Not Used
Not Used
Not Used
Not Used
Not Used
Start Pulse for Pre Imprinter
CTS(for Pre Imprinter)
RTS(for Pre Imprinter)
RXD(for Pre Imprinter)
TXD(for Pre Imprinter)
DAC Load(Motor Drive)
Ground
Ground
Description
Ground
Ground
Reset
+3V(for Digital)
+3V(for Digital)
CPU Address Strobe
CPU Write
CPU Read
Ground
Ground
CPU Data
CPU Data
CPU Data
CPU Data
+5V(for Digital)
+5V(for Digital)
CPU Data
CPU Data
CPU Data
CPU Data
CN602 (SCSI) - CN2002 (MOTHER)
Pin No.
Signal Name
21
GND
22
GND
23
CPUA8
24
CPUA7
25
CPUA6
26
CPUA5
27
CPUA4
28
CPUA3
29
CPUA2
30
CPUA1
31
CPUA0
32
+5VD
33
GND
34
GND
35
*VERCS
36
*IRQ(IMG)
37
*IRQ1(SCSI)
38
*CS3(SCSI)
39
CTS2(IF)
40
RTS2(IF)
41
+3VD
42
RXD2(IF)
43
TXD2(IF)
44
*SCWAIT
45
TERMPC
46
*ACTTERM
47
*CS(IMG)
48
BVD7
49
GND
50
GND
51
BVD6
52
BVD5
53
BVD4
54
BVD3
55
BVD2
56
BVD1
57
+3VD
58
BVD0
59
FVD7
60
FVD6
61
FVD5
62
GND
63
GND
64
FVD4
65
FVD3
66
FVD2
67
FVD1
68
FVD0
69
+3VD
70
+3VD
71
GND
72
BCLK
73
FCLK
74
BEN
75
FEN
76
GND
77
VSYNC
78
+5VD
79
GND
80
GND
(continued)
Description
Ground
Ground
CPU Address
CPU Address
CPU Address
CPU Address
CPU Address
CPU Address
CPU Address
CPU Address
CPU Address
+5V(for Digital)
Ground
Ground
Chip Select for I/F Board Detect
GAIMG Interrupt Request
SCSI Interrupt Request
Chip Select for SCSI
Not Used
Not Used
+3V(for Digital)
Not Used
Not Used
CPU Wait
Terminal Power Control
Active Terminator Enable
Chip Select for GAIMG
Back Data
Ground
Ground
Back Data
Back Data
Back Data
Back Data
Back Data
Back Data
+3V(for Digital)
Back Data
Front Data
Front Data
Front Data
Ground
Ground
Front Data
Front Data
Front Data
Front Data
Front Data
+3V(for Digital)
+3V(for Digital)
Ground
Not Used
Not Used
Back Line Enable
Front Line Enable
Ground
Page Enable
+5V(for Digital)
Ground
Ground