Specifications

4. Specifications
Model name
Power supply
(1)
1
Cooling capacity at T1
Capacity
Capacity
EER
EER
PI
(2)
1
Cooling capacity at T1
Capacity
Capacity
EER
EER
PI
Cooling capacity at T3 1
Capacity
Capacity
EER
EER
PI
CSPF 3
Power factor
Cooling capacity at T4 1
Capacity
Capacity
EER
EER
PI
Heating capacity at H1 1
Capacity
Capacity
COP
COP
PI
Allowed indoor capacity
Nom.
index connection
Min.
Max.
Dimensions
Unit
(H×W×D)
Packed unit
Mass
Unit
Packed unit
Heat
Type
exchanger
Fan
Type
Discharge direction
Motor
Quantity
Model
Output/pcs
Airflow
Cooling
rate
Heating
Compressor
Quantity
Motor
Quantity
Model
Type
Refrigerant
Refrigerant name
Charge
Piping
Liquid
Type
connections
Diameter (OD)
Gas
Type
Diameter (OD)
Safety devices
Standard accessories
Drawing No.
Notes:
1. The above data are based on the following conditions.
Condition
Indoor DB (°C)
(1)
T1
27.0
(2)
T1
26.6
T3
29.0
T4
26.6
H1
20.0
2. For detailed contents, see installation/operational manual.
3. Cooling seasonal performance factor for hot climates at T3 condition as per ISO 16358-1:2013/AMD 1:2019
12
RXYMQ4AVMK
1 phase, 220-240 V, 50/60 Hz
kW
Btu/h
38,500
kW/kW
Btu/W·h
14.00
kW
kW
Btu/h
38,500
kW/kW
Btu/W·h
14.10
kW
kW
Btu/h
35,400
kW/kW
Btu/W·h
10.70
kW
W/W
kW
Btu/h
34,400
kW/kW
Btu/W·h
10.10
kW
kW
Btu/h
43,000
kW/kW
Btu/W·h
16.04
kW
mm
870×1,100×460
mm
1,010×1,190×560
kg
kg
Cross fin coil
Propeller
Brushless DC
W
m³/min
m³/min
Inverter
Hermetically sealed swing type
R-410A
kg
Flare connection
mm
Flare connection
mm
High pressure switch, Fan driver overload protector,
Inverter overload protector, Fuse,
Bimetal thermostat (external overload relay)
Installation manuals, Operation manual,
Ferrite core, etc.
C: 2D135391B
Indoor WB (°C)
19.0
19.4
19.0
19.4
11.3
4.10
2.75
11.3
4.13
2.73
10.4
3.14
3.31
5.80
0.9
10.1
2.96
3.41
12.6
4.70
2.68
100
50
130
100
114
Side
1
234
87
94
1
1
4.2
9.5
15.9
High pressure switch, Fan driver overload protector,
Outdoor DB (°C)
Outdoor WB (°C)
35.0
35.0
46.0
48.0
7.0
SiME332106E
RXYMQ4AYFK
3 phase, 380-415/400 V, 50/60 Hz
11.3
38,500
4.07
13.90
2.77
11.3
38,500
4.09
13.95
2.76
10.6
36,200
3.14
10.70
3.38
5.70
0.9
10.1
34,400
2.97
10.15
3.39
12.6
43,000
4.50
15.37
2.80
100
50
130
870×1,100×460
1,010×1,190×560
120
134
Cross fin coil
Propeller
Side
1
Brushless DC
600
123
145
1
1
Inverter
Hermetically sealed swing type
R-410A
4.95
Flare connection
9.5
Brazing connection
15.9
Inverter overload protector, Fuse,
Bimetal thermostat (external overload relay),
Over/under voltage protection PCB
Installation manuals, Operation manual,
Auxiliary pipe, etc.
C: 2D135391B
Reference standard
ISO 15042:2011
AHRI-1230
ISO 15042:2011
AHRI-1230
6.0
ISO 15042:2011
Part 1 General Information