SiME332106E
Mode
First
No.
Code
Description
(2)
No.
Ceiling height setting, Setting of
0
normal airflow
1
Airflow direction setting
Swing pattern settings
2
3
Airflow function setting
(5)
Airflow direction adjustment
4
range
13 (23)
Setting of static pressure
5
selection
External static pressure
6
settings
Setting of swing patterns when
7
cooling thermostat is OFF
13
Setting of circulation airflow
14
Circulation airflow patterns
Switching panel type
15
Humidification when heating
1
thermostat is OFF
2
Direct duct connection
15 (25)
Drain pump and humidifier
3
interlock selection
5
Individual ventilation setting
Display of error codes on the
4
remote controller
1b
Setting restricted/permitted of
14
airflow block
0
Room temperature display
01
Thermostat sensor
(5)
1c
12
Window contact B1
(5)
13
Key card contact B2
(5)
Setback function
02
1e
(5)
07
Rotation overlap time
1B
Daylight saving time
08
(5)
Note(s)
1. Settings are made simultaneously for the entire group, however, if you select the mode No. inside
parentheses, you can also set by each individual unit. Setting changes however cannot be checked except
in the individual mode for those in parentheses.
2. The mode numbers inside parentheses cannot be used by wireless remote controllers, so they cannot
be set individually. Setting changes also cannot be checked.
3. Do not make settings other than those described above. Nothing is displayed for functions the indoor unit
is not equipped with.
4. 88 or Checking the connection. Please stand by. may be displayed to indicate the remote controller is
resetting when returning to normal mode.
5. BRC1H81 series only
Part 5 Field Settings and Test Operation
Second Code No.
01
02
Refer to the page on the right for details.
4-way airflow
3-way airflow
All direction
synchronized
—
swing
Equipped
Not equipped
Refer to the page on the right for details.
High static
Standard
pressure
Refer to the page on the right for details.
Refer to the page on the right for details.
Disabled
Enabled
Pattern 1
Pattern 2
Standard
Designer panel
panel
Not equipped
Equipped
Not equipped
Equipped
Not
Interlocked
interlocked
Normal
Individual
—
Two-digit display
Refer to the page on the right for details.
Not displayed
Displayed
Indoor unit
Controller
thermistor
thermistor
Do not use
Use
Do not use
Use
No Setback
Heating only
30 minutes
15 minutes
Automatic
Disable
changeover
Field Settings for Indoor Unit
03
04
2-way airflow
—
Facing
—
swing
—
—
—
—
—
—
Pattern 3
Pattern 4
—
—
—
—
—
—
—
—
—
—
Four-digit
—
display
—
—
—
—
—
—
—
—
Heating and
Cooling only
Cooling
10 minutes
5 minutes
Manual
Centralized
changeover
control
Reference
Page
101
101
102
—
102
102
103
103
103
104
104
104
105
105
105
105
106
106
—
—
—
—
—
—
91