XCMG XE210C Operating & Maintenance Manual page 96

Hydraulic excavator
Table of Contents

Advertisement

XE210C Hydraulic Excavator
with the mixed fluid composing of anti-freeze fluid and soft water. The mixing rate of anti-freeze
fluid refers to List 1-19, normally between 30% and 50%. If the rate is less than 30%, the system
will be rusted; if the rate is over 50%, engine will be overheated.
d)
Mixing rate list of anti-freeze fluid
Temperature
Attention:
1)
Anti-freeze fluid is poisonous. If taken in, it will result in a severe casualty accident. Once
drinking it by mistake, the patient should be channeled off to vomit and obtain an immediate
emergent treatment.
2)
While storing anti-freeze fluid, make sure to store it in a container with sealing cap and
remarkable mark. Always keep it away from the contact with children.
3)
If anti-freeze fluid is splashed into eyes carelessly, you should wash your eyes with water for
10-15 min. and then seek out an emergent treatment.
4)
When storing or abandoning anti-freeze fluid, you must abide by all the local regulations.
List 1-19 Parameter list
Mixing rate
-1
30
-4
30
-7
30
-l1
30
-15
35
-20
40
-25
45
-30
50
Operating and Maintenance Manual 96
Mixing capacity
Anti-freeze fluid
L
6.9
6.9
6.9
6.9
8.1
9.2
10.4
11.5
Soft water
L
16.1
16.1
16.1
16.1
14.9
13.8
12.6
11.5

Hide quick links: