cooling water
Low pressure of engine
oil
Excessive consumption
of engine oil
Excessive consumption
of engine fuel
Too
black
or
grey
exhaust fume
Failure of engine
Insufficient capacity of
battery
Starting
motor
can't
rotate.
Magnetic vibration of
starting motor
Trouble of thermometer or transfer
unit
Trouble of engine oil pump or pump
drive
Low level of engine oil
trouble of engine oil pressure control
valve
Blockage of oil pump suction mesh
enclosure
Blockage of oil filter
Leak of engine oil
Engine oil is diluted by fuel or
cooling water.
Overhigh temperature of engine
Wrong engine oil
Wrong engine oil
Leak of engine oil
Overheat of engine
Blockage of air filter
Wear of inner parts of engine
Blockage or dirt of air suction system
Wrong fuel
Dirty fuel nozzle
Off-time of injection pump
Wrong fuel
Blockage or dirt of air suction or
discharge system
Off-time of injection pump
Dirty fuel nozzle or its incorrect
operation
Trouble of engine body
Trouble of battery
Loose connection or corrosion
Loosening of AC generator belt
AC generator fails to charge.
Broken fuse
Trouble of key switch
Insufficient capacity of battery or
damaged
Poor connection of battery circuit
Broken fuse
Trouble of key switch
Trouble of starting relay
Trouble of starting motor magnetic
coil
Trouble of starting motor
The starting motor pinion is clamped
in the flywheel gear.
Trouble of engine body
Poor connection of battery or starting
motor circuit
Low capacity of battery
Opening of starting motor magnetic
"hold" coil
Operating and Maintenance Manual 133
Contact with the assigned dealer of XEM excavator.
Contact with the assigned dealer of XEM excavator.
Add in engine oil.
Contact with the assigned dealer of XEM excavator.
Contact with the assigned dealer of XEM excavator.
Renew the oil filter.
Leak check.
Contact with the assigned dealer of XEM excavator.
Check the cooling system.
Drain the oil, and adopt the correct oil.
Drain the oil, and adopt the correct oil.
Check the engine oil drain plug.
Check the cooling system.
Clean the filter element or attach new filter elements.
Contact with the assigned dealer of XEM excavator.
Clean the air suction system.
Adopt the correct fuel.
Contact with the assigned dealer of XEM excavator.
Contact with the assigned dealer of XEM excavator.
Empty the oil tank, and adopt the correct fuel.
Clean the air suction or discharge system.
Contact with the assigned dealer of XEM excavator.
Contact with the assigned dealer of XEM excavator.
Contact with the assigned dealer of XEM excavator.
Charge or replace.
Clean, tighten or replace the battery.
Tension the belt or attach a new belt.
Contact with the assigned dealer of XEM excavator.
Replace the fuse.
Replace the key switch.
Charge or replace the battery.
Clean the connection.
Replace the fuse.
Contact with the assigned dealer of XEM excavator.
Contact with the assigned dealer of XEM excavator.
Contact with the assigned dealer of XEM excavator.
Repair or replace the starting motor.
Repair or replace starting motor.
Contact with the assigned dealer of XEM excavator.
Clean the connection part.
Charge or replace battery
Contact with the assigned dealer of XEM excavator.