Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Operation
18 |
©
Danfoss | July 2019
Typical operating curve
Hysteresis
1
EDC Hysteresis
Input hysteresis
Output hysteresis @50% displacement
1
Values may vary depending on application conditions. For more information, please contact Danfoss Power
Solutions
Response/Recovery
Response/Recovery Times @ 1500rpm (50°C)
Response 0%-100%
Response 100%-0%
MOR
Each Electric Displacement Control (EDC) is equipped with a Manual Over Ride (MOR) function for
temporary actuation of the control to aid in diagnostics, even if insufficient or no current is supplied to
the solenoid actuator. Initial activation of the MOR function will require a higher force to overcome the
sticking effect between the pin and O-ring seal. Repeated activation of this functionality should provide
better controllability.
<4.5%
<4.0%
1
130cc (263 bar)
145cc (263 bar)
193cc (160 bar)
260cc (200 bar)
130cc (263 bar)
145cc (263 bar)
193cc (160 bar)
260cc (200 bar)
260 msec
260 msec
272 msec
370 msec
390 msec
390 msec
186 msec
390 msec