Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Operation
12 |
©
Danfoss | July 2019
S characteristic
Q max
0
0
Pressure
For additional system protection, install a relief valve in the pump outlet line.
NPSN Priority
The Pressure Compensated Control (P) has priority over the Load Sensing Control (S).
Response/Recovery
Load Sensing (LS) Response/Recovery Times @80°C, 1500rpm, LS Setting at 25 bar
Frame Size
130cc
145cc
1
193cc
260cc
1
Tested with a LS setting of 20bar
Values may vary depending on application conditions. For more information, please contact Danfoss
Power Solutions
Response (msec)
260
260
233
309
Recovery (msec)
360
360
264
327
L1527453 | AX00000292en-CN0201