Connecting T1 Cas Telephony Cables For A Cisco Unified Meetingplace 8112 - Cisco 700 MHz Installation And Upgrade Manual

Audio server
Hide thumbs Also See for 700 MHz:
Table of Contents

Advertisement

Chapter 2
Installing the Cisco Unified MeetingPlace 8100 Series Hardware
To Connect the T1 CAS Telephony Cables for a Cisco Unified MeetingPlace 8106
Step 1
Locate the T1 CAS telephony cables that shipped with the Cisco Unified MeetingPlace system. Each T1
CAS telephony cable has an RJ-48 connector on each end.
Step 2
Plug one end of the first T1 CAS telephony cable into the socket.
Step 3
Plug the other end of the first T1 CAS telephony cable into the T1 Smart Blade transition module in the
back of the Cisco Unified MeetingPlace 8106. Place the first T1 CAS telephony cable in the slot nearest
the right edge. (See
Repeat
Step 4
a.
b.
c.
Step 5
Install tie wraps and label the T1 CAS telephony cables as needed.

Connecting T1 CAS Telephony Cables for a Cisco Unified MeetingPlace 8112

Each T1 Smart Blade transition module has connectors for four trunk lines in the back of the Cisco
Unified MeetingPlace Audio Server.
Looking at the back of the Cisco Unified MeetingPlace Audio Server, the T1 Smart Blade transition
modules begin in slot 1 on the right and move to the left. The cables go from top to bottom in the right
most slot, then from top to bottom in the second most right slot, and so on to the left most slot, where
they continue going from top to bottom.
Table 2-2
Table 2-2
Connector
Connector
Connector
Connector
The number of T1 CAS telephony cables that Cisco Systems ships with the Cisco Unified MeetingPlace
system depends on the number of ports being activated. Cisco Systems ships one T1 CAS telephony
cable for every 24 ports.
Figure 2-9
ports. Four T1 CAS telephony cables connect to each of the 12 T1 Smart Blade transition modules for a
total of 48 T1 CAS telephony cables. Each cable holds 24 ports for a total of 1,152 ports
(48 x 24 = 1,152).
OL-13417-01
Table
2-1.)
Step 2
and
Step 3
until all the T1 CAS telephony cables are connected:
Place the second T1 CAS telephony cable in the second connector slot from the right.
Place the third T1 CAS telephony cable in the third connector slot from the right.
Place the fourth T1 CAS telephony cable in the fourth connector slot from the right.
shows the order in which the cables should be placed. Note that slots 7 to 10 are reserved.
Cable Locations in the Cisco Unified MeetingPlace 8112
Slot
Slot
Slot
16
15
14
45
41
37
46
42
38
47
43
39
48
44
40
shows the cable connections for a Cisco Unified MeetingPlace 8112 with 1,152 T1 CAS
Installation and Upgrade Guide for Cisco Unified MeetingPlace Audio Server 6.x
Connecting the Cables to the Cisco Unified MeetingPlace 8100 Series
Slot
Slot
Slot
Slot
13
12
11
33
29
25
34
30
26
35
31
27
36
32
28
Slot
Slot
Slot
Slot
6
5
4
3
21
17
13
9
22
18
14
10
23
19
15
11
24
20
16
12
Slot
2
1
5
1
6
2
7
3
8
4
2-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

8Meetingplace

Table of Contents