Parts Included With Indoor Unit; Installer Supplied Parts; Condensate Pump - Sea Breeze SHE9A423ZGX Installation Manual

Table of Contents

Advertisement

Indoor unit
Wall Bracket
Remote Control
Batteries for Remote Control (2 AAA)
Remote Control Holder
Drain Tubing 6 ft.
Operation Manual
ADAPTER INCLUDED WITH INDOOR UNIT IS NOT NEEDED FOR SINGLE ZONE
INSTALLATION
The following additional Items are required for proper installation.
Refrigerant line set: Insulated copper tubing:
9K Indoor – 1/4" (liquid line) and 3/8" (suction line).
o
12K Indoor – 1/4" (liquid line) and 1/2" (suction line).
o
18K Indoor – 1/4" (liquid line) and 1/2" (suction line)
o
24K Indoor – 1/4" (liquid line) and 5/8" (suction line).
o
Flare nuts 2 ea. required per line, see above (line set) for size.
Vinyl UV resistant tape.
Supply Power:
SHE18A418ZOGX, SHE24A418ZOGX, SHE18H418ZOGX, SHE24H418ZOGX
o
20 amp circuit breaker, #12 AWG (minimum) copper wire from outdoor unit to power
disconnect
SHE9A423ZOGX, SHE12A422ZOGX, SHE9H423YOGX, SHE12H422ZOGX
o
15 amp circuit breaker, #14 AWG (minimum) copper wire from outdoor unit to power
disconnect
Interconnect wire cable:
o
4C - 14 AWG (Recommended) 4C - 16 AWG (Minimum)
Refrigerant - R410A required for additional line set charge.
Sealing putty.
1/4" to 5/16" access fitting adaptor (PN: QC-S5)
Mounting hardware - Wall anchors, condenser pad etc.
Optional: Condensate pump, miniature, 230 VAC P/N DE05LUB110 (4100130).
Condensate pump, accessory kit P/N GC1KFX2010 (4100124).
Surge protector (highly recommended)
Note: Condensate pump P/N 4100130 cannot be connected to the indoor unit. Power connections must be
made at outdoor unit supply power.
Main system breaker or disconnect sized per unit requirements should be mounted adjacent to outdoor unit.
950-0192revA