Parts Included With Indoor Unit; Installer Supplied Parts - Sea Breeze SMZ18H46ZOGX Installation Manual

High efficiency series mini-split dual / triple / quad zone
Table of Contents

Advertisement

Wall-mounted Indoor unit
Wall Bracket
Remote Control
Batteries for Remote Control (2 AAA)
Remote Control Holder
Adapter - Dual Zone requires 1/2"F to 3/8"M
(9510198) with 9K and/or 12K indoor unit(s).
Quad Zone requires 3/8"F to 1/2"M (9510197)
with 18K and/or 12K indoor unit(s).
Operation Manual
Drain Tubing 6 ft.
Note: The outdoor unit can also be connected to different types of indoor units as followings:
Console: 9K - SMZC9H4ZIGX; 12K - SMZC12H4ZIGX; 18K - SMZC18H4ZIGX.
Cassette: 12K - SMZCA12H4ZIGX; 18K - SMZCA18H4ZIGX.
Floor / Ceiling: 9K - SMZFC9H4ZIGX; 12K - SMZFC12H4ZIGX; 18K - SMZFC18H4ZIGX.
Ducted: 9K - SMZD9H4ZIGX; 12K - SMZD12H4ZIGX; 18K - SMZD18H4ZIG.
For the detail information about the included parts and connecting for above indoor units, please refer to the
manual to be included with each indoor unit.
The following additional Items are required for proper installation.
Refrigerant line set: Insulated copper tubing:
9K Indoor – 1/4" (liquid line) and 3/8" (suction line).
o
12K Indoor – 1/4" (liquid line) and 1/2" (suction line) for SHE12H4ZIGX;
o
18K Indoor – 1/4" (liquid line) and 1/2" (suction line).
o
Flare nuts 2 ea. required per line, see above (line set) for size.
Vinyl UV resistant tape.
Supply Power:
Dual Zone SMZ18H46ZOGX
o
20 amp circuit breaker
Triple Zone SMZ24H46ZOGX
o
30 amp circuit breaker
Quad Zone SMZ30H46ZOGX
o
45 amp circuit breaker
Interconnect wire cable for all units
o
4C 14 AWG stranded (Recommended) 16 AWG stranded 4C (min
Refrigerant - R410A required for additional line set charge.
Sealing putty.
1/4" to 5/16" access fitting adaptor (PN: QC-S5)
Mounting hardware - Wall anchors, condenser pad etc.
Surge protector (highly recommended)
Note: Condensate pump cannot be powered from the indoor unit. Power connections must be made at outdoor
unit supply power.
Main system breaker or disconnect sized per unit requirements should be mounted adjacent to outdoor unit.
950-0195revJ
PARTS INCLUDED WITH UNIT

INSTALLER SUPPLIED PARTS

1/4" (liquid line) and 3/8" (suction line) for SHE12H4ZIGB
Outdoor Unit
Drain Fitting
Installation Manual
Terminal Label
- 4 -
per indoor unit.
)