enabled. Details refer to 4.1 protections. When the working environment temperature
exceeds 50° C, the actual load power needs to be derated. With every increase of 1° C, the
actual load power needs to be reduced by 2.57% of the rated load power. For example,
when the working temperature reaches 60℃, the actual rated power for load 1 will be
100W-0.0257*(60-50)*100=74.3W. The load power variation curve with temperature is
shown in the figure below:
Load 1 Power reduction curve
Mechanical parameters
Model
Dimension
173×158×77.1mm
(L x W x H)
Mounting
size (L x W)
Mounting
hole size
Grounding
terminal
Recommend
ed grounding
cable
Net Weight
MSC2210N
120×149mm
8AWG
2
(10mm
)
1.2kg
Load 2 Power reduction curve
MSC3210N
178×162×80.1mm
120×153mm
Φ5mm
RNB14-5
8AWG
2
(10mm
)
1.4kg
33
MSC4210N
MSC4215N
213.2×192×96.6mm
150×182mm
6AWG
6AWG
2
(16mm
)
(16mm
2.4kg
2.4kg