Advertisement

Battery type
Voltage
parameters
Over Voltage
Disconnect Voltage
Charging Limit
Voltage
Over Voltage
Reconnect Voltage
Equalize Charging
Voltage
Boost Charging
Voltage
Float Charging
Voltage
Boost Reconnect
Charging Voltage
VLVR (Low voltage
reconnect voltage)
Under Voltage
Warning Reconnect
Voltage
Under Voltage
Warning Voltage
VLVD (Low Voltage
Disconnect Voltage)
Discharging Limit
Voltage
Equalize Duration
Boost Duration
The following rules must be observed when modifying the parameter values
in User for a lead-acid battery.
A. Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging
Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect
Sealed
16.0V
15.0V
15.0V
14.6V
14.4V
13.8V
13.2V
12.6V
12.2V
12.0V
11.1V
10.6V
120 minutes
120 minutes
13
GEL
16.0V
15.0V
15.0V
--
14.2V
13.8V
13.2V
12.6V
12.2V
12.0V
11.1V
10.6V
--
120 minutes
User
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
0~180 minutes
10~180 minutes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc2210nMsc3210nMsc4210nMsc4215n