Others; Protection - Epever MSC-N Series User Manual

Mppt solar charge controller
Table of Contents

Advertisement

4 Others

4.1 Protection

Protection
PV limit
Current/limit power
protection
PV short circuit
protection
PV reverse polarity
protection
Night reverse
charging protection
Battery reverse
protection
Battery over-voltage
protection
Battery over-
discharging
protection
When the charging current/power of the PV array exceeds
the rated charging current/power, the PV array will charge
the battery as per the rated charging current/power.
When not in the PV charging state, the controller will not be
damaged in the case of a short-circuiting in the PV array.
When the polarity of the PV array is reversed, the controller
may not be damaged and resume normal operation after
the mis-wiring is corrected.
NOTE: If the PV array is reversed and the actual power is 1.5
times the rated power of the controller, the controller will be
damaged.
Prevent the battery from discharging to the PV module at
night.
When the polarity of the battery is reversed, the controller
may not be damaged and resume normal operation after
the mis-wiring is corrected.
NOTE:
The
controller,
characteristic, will be damaged when the PV array connection
is right and the battery connection is reversed.
When the battery voltage reaches the over voltage
disconnect voltage, the PV array will automatically stop
charging the battery to prevent battery damage due to
overcharging.
When the battery voltage reaches the low voltage
disconnect voltage, battery discharging will automatically
stop to prevent the battery from damaging due to over-
discharging.
Instruction
limited
to
25
the
lithium
battery

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc2210nMsc3210nMsc4210nMsc4215n

Table of Contents