① If the load current exceeds 1.05 times the controller's rating current, the controller will
cut off the output after 30 seconds delay. In case of overload, the controller is restarted at
intervals of 5 seconds, 10 seconds, 15 seconds, 20 seconds, 25 seconds, 30 seconds, and
1 hour until the power of all the loads is reduced to the rated power.
Battery
overheating
Controller
overheating
System voltage
error
Over load
Load short circuit
While the temperature declines
below 55 º C, the controller will
resume.
When the heat sink of the controller
exceeds 85℃, the controller will
automatically cut off the input and
output circuit. When the temperature
is below 75℃, the controller will
resume work.
① Check whether the current battery
voltage matches the system voltage
set by the controller.
② Please change a suitable battery
or reset the system voltage.
① Please reduce the number of
electric equipment.
② Restart the controller or press the
button to clear faults.
①Check carefully load connection,
and clear the fault.
②Restart the controller, or press the
button to clear faults.