Epever MSC-N Series User Manual page 27

Mppt solar charge controller
Table of Contents

Advertisement

Note: Disconnect the system in the reverse order. Namely, disconnect the
system in the order of ④ PV array -- ③ battery -- ② load 2-- ① load 1.
 When wiring the controller, please do not connect the circuit
 A fuse whose current is 1.25 to 2 times the rated current of the
 Suppose the controller is to be used in frequent lightning strikes
CAUTION
 Suppose an inverter is to be connected to the system. In that case,
Step 3:Grounding
MSC-N series are common-negative controllers; all the negative terminals can be
grounded simultaneously, or anyone is grounded. However, according to the
practical application, the negative terminals of the PV array, battery, and load can
also be ungrounded. Still, the grounding terminal on the shell must be grounded. It
effectively shields the electromagnetic interference from the outside and prevents
some electric shock to the human body.
breaker or fuse and ensure that the electrode polarity is correctly
connected.
controller must be installed on the battery side with a distance from
the battery no longer than 150 mm.
or unsupervised areas. In that case, an external surge arrester
must be installed on the input side of the PV array.
you must connect the inverter directly to the battery, not to the load
side of the controller.
3
23
4