Dräger X-am 2800 Technical Manual page 18

Hide thumbs Also See for X-am 2800:
Table of Contents

Advertisement

Troubleshooting
Code
3xx
4xx
Code
150
152
156
159
163
165
175
182
183
185
x51
x52
x53
x54
x56
x69
x70
x71
x73
x77
18
Sensor channel
EC1
EC2
Cause
Ambient pressure too high.
Customer's life time counter will
expire soon.
Ambient pressure too low.
Calibration not possible. Menu
function cannot be performed as a
notice exists that prevents the
function (e.g. sensors warming
up).
Life time expired.
Error sent from Bluetooth control. Switch the gas detector off and
Bluetooth connection interrupted. Reconnect the device.
Device temperature too high.
Device temperature too low.
Battery pre-alarm
Sensor warming up (warm-up 1).
Followed by measurement
standby, bump test standby
Sensor warming up (warm-up 2).
Followed by calibration standby
Value negative.
Temperature too high.
Calibration interval has expired.
Bump test expired.
Bump test interval expires soon.
Calibration expires soon
(CatEx thermal conduction range).
Calibration expired
(CatEx thermal conduction range).
Temperature too low.
Code
Sensor channel
6xx
EC4
Remedy
Operate gas detector within per-
mitted ambient pressure range.
Reset life time counter with Dräger
CC-Vision.
Operate gas detector within per-
mitted ambient pressure range.
Determine notice code using the
Info menu and disable if neces-
sary.
Reset life time counter with Dräger
CC-Vision.
then on again / Contact DrägeSer-
vice.
Operate gas detector within per-
mitted temperature range.
Operate gas detector within per-
mitted temperature range.
Charge or replace battery.
Wait until warm-up time is com-
plete.
Wait until warm-up time is com-
plete.
Perform a fresh air calibration.
Operate gas detector within per-
mitted temperature range.
Carry out the span calibration.
Carry out bump test.
Carry out bump test.
Carry out the span calibration.
Carry out the span calibration.
Operate gas detector within per-
mitted temperature range.