Emi/Cooling Shield - HP Compaq SP750 Maintenance And Service Manual

Professional workstation
Hide thumbs Also See for Compaq SP750:
Table of Contents

Advertisement

4-8 Compaq Professional Workstation SP750 Maintenance and Service Guide

EMI/Cooling Shield

An EMI/cooling shield covers bays 5 and 6 to provide proper cooling and EMI protection. To
remove the EMI/cooling shield:
1. Perform the steps in the "Service Preparations" section in this chapter, then place the
workstation on its side.
2. Remove the following components:
Y
Side access panel
Y
Front bezel
3. Remove the two screws that connect the EMI/cooling shield to the front of the chassis.
4. Remove the EMI/cooling shield from the drive slot.
Figure 4-6. Removing the EMI/cooling shield
IMPORTANT: Replace the shield after the drive is installed in the bay.
To replace the EMI/cooling shield, reverse the above procedure.
CAUTION: Before removing the side access panel, ensure that the workstation is turned off, all
cables are disconnected from the back of the workstation, and the power cord is disconnected
from the grounded AC outlet.

Advertisement

Table of Contents
loading