14 Hardware Interface

14.6.6 Master / Slave Camera Connection

The line output of one Photonfocus GigE camera can easily be connected to a line input of
another Photonfocus GigE camera as shown in Fig. 14.10. This results in a master/slave mode
where the slave camera operates synchronously to the master camera.
A pull up resistor is necessary, when an open drain output (ISO_OUT0 or
ISO_OUT1) is used, which is shown in the connection A in Fig. 14.10. When
ISO_OUT2 is used (see connection B in Fig. 14.10), which is a high speed TTL out-
put, it can be connected to any of the four single ended input without a pull up
resistor.
Camera
Isolator
LineOut0
LineOut1
LineOut2
Figure 14.10: Master / slave connection of two Photonfocus GigE cameras
.
110 of 143
CAMERA_PWR
2
12
1
11
CAMERA_GND
ISO_OUT0
13
ISO_OUT1
14
ISO_OUT2
10
17
ISO_GND
17-pin M12
I/O Connector
2
12
1
11
YOUR_POWER
TTL or SE-HTL
4.7k
ISO_IN0
3
A
4
ISO_IN1
5
6
ISO_IN2
7
B
8
TTL120
ISO_IN3
9
17
YOUR_GND
ISO_GND
Camera
CAMERA_PWR
CAMERA_GND
Isolator
C0
LineIn0
R0
C1
LineIn1
R1
C2
LineIn2
R2
10nF
LineIn3
120
¡