10 Technical Parameters

10 Technical Parameters
Technical Data
Input
Max.Input Power (kW)
Max.Input Voltage (V)
MPPT Operating Voltage Range
(V)
MPPT Voltage Range at Nominal
Power (V)
Start-up Voltage (V)
Nominal Input Voltage (V)
Max. Input Current per MPPT (A)
Max. Short Circuit Current per
MPPT (A)
Max. Backfeed Current to The
Array (A)
Number of MPPT
Number of Strings per MPPT
Output
Nominal Output Power (kW)
Nominal Output Apparent Power
(kVA)
Max. AC Active Power (kW)
Max. AC Apparent Power (kVA)
Nominal Power at 40°C(kW)
Max Power at 40°C(Including AC
Overload) (kW)
Nominal Output Voltage (V)
Output Voltage Range (V)
Nominal AC Grid Frequency (Hz)
AC Grid Frequency Range (Hz)
Max. Output Current (A)
Max. Output Fault Current (peak
and duration) (A)
GW100K-HT
GW110K-HT
150
165
1100
1100
180~1000
180~1000
500~850
500~850
200
200
600
600
30
30
45
45
0
0
10
12
2
2
100
110
*1
100
1
110
*
110
121
*1*4
110
121
*1*5
100
110
110
121@400V
400, 3L/N/PE or 3L/PE
320~440
50 / 60
50 / 60
167.0
175.5
364@5μs
364@5μs
48
User Manual V1.1-2022-07-20
GW120K-HT
180
1100
180~1000
500~850
200
600
30
45
0
12
2
120
120
132
*4
*4
132
*5
*5
120
132@400V
*2
50 / 60
45~55/55~65
191.3
364@5μs
GW136K-HTH
205
1100
180~1000
500~850
200
750
30
45
0
12
2
136
136
150
*4
150
*5
136
150
500 , 3L/PE
425~550
50 / 60
173.2
364@5μs

Advertisement