Test Options

Navigate: Main Menu → Home/Test → Test
Run a self-test program on features and attributes of the Cyberlight LED fixture. When you run
the test, the display indicates "Running" and the fixture automatically runs a self-test
procedure, testing each of the functions. Press [MODE/ESC] button to end the self-test and
return the display to the previous menu.
All - runs a self-test on all mechanical features of the fixture including pan, tilt, color, gobo
wheels, diffusion, and lenses
Pan/Tilt - runs a self-test on the pan and tilt
Color - runs a self-test on the color wheel
Apertures - runs a self-test on the gobo wheels
Effects - runs a self-test on the primary (radial) diffuser and the prism
Lenses - runs a self-test on the optics system
Light Engine - runs a self-test on the light engine

Diagnostics Menu

Navigate: Main Menu → Diagnostics

Set Time Options

Navigate: Main Menu → Diagnostics → Time
Parameter
Total Fixture Hours
Fixture Hours
Total LED Hours
LED Hours
Reset

View Errors

Navigate: Main Menu → Diagnostics → Errors
Errors that are present in the fixture are shown. Errors will automatically clear from the list as
they are mitigated. See

View Fan Speed

Navigate: Main Menu → Diagnostics → Fan Speed
Displays the speeds (in %) of the fixture's fans.
Configure the Fixture
Value
Description
Read only
Total run time of the fixture, shown in hours (h). The
value in
counter cannot be reset by the user.
hours
Read only
Run time of the fixture since the last reset, shown in
value in
hours (h). The counter is reset only from the Reset
hours
option, which is passcode protected.
Read only
Total run time of the LED engine, shown in hours (h).
value in
The counter cannot be reset by the user.
hours
Read only
Run time of the LED engine since the last reset, shown
value in
in hours (h). The counter is reset only from the Reset
hours
option, which is passcode protected.
This protected menu provides access to reset Fixture
Enter
and LED hours. As needed, contact Technical Support
Passcode
at ETC for access. See
page 2
Error Codes on page 38
Help from Technical Services on
.
for information about the errors.