The controller can only set the lead-acid battery type. The lithium battery type must
be set through the PC or APP.
CAUTION
④ Battery voltage control parameters
Lead-acid battery parameters
The parameters are measured in the condition of 12V/25 º C. Please double the values in the 24V system
and quadruple the values in the 48V system.
Voltage control
parameters
Over voltage disconnect
voltage
Charging limit voltage
Over voltage reconnect
voltage
Equalize charging voltage
Boost charging voltage
Float charging voltage
Boost reconnect charging
voltage
Low voltage reconnect
voltage
Under voltage warning
reconnect voltage
Under voltage warning
voltage
Low voltage disconnect
voltage
Discharging limit voltage
Equalize Duration
Boost Duration
⑴ To change these parameters, select "User" battery type.
⑵ The following rules must be observed when modifying the parameter's value in user battery type
(factory default value is the same as sealed type):
A. Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging Voltage ≥ Boost
Charging Voltage ≥ Float Charging Voltage > Boost Reconnect Charging Voltage.
B. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
C. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging Limit Voltage.
D. Under Voltage Warning Reconnect Voltage>Under Voltage Warning Voltage≥ Discharging Limit
Voltage;
Sealed
16.0V
16.0V
15.0V
15.0V
15.0V
15.0V
14.6V
14.4V
14.2V
13.8V
13.8V
13.2V
13.2V
12.6V
12.6V
12.2V
12.2V
12.0V
12.0V
11.1V
11.1V
10.6V
10.6V
120 minutes
120 minutes
120 minutes
17
GEL
FLD
16.0V
15.0V
15.0V
--
14.8V
14.6V
13.8V
13.2V
12.6V
12.2V
12.0V
11.1V
10.6V
--
120 minutes
120 minutes
User
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
0~180 minutes
10~180 minutes