 The wire size is only for reference. Suppose a long distance exists between the PV
array and the controller or between the controller and the battery. In that case,
larger wires shall be used to reduce the voltage drop and improve the system
performance.
CAUTION
 The recommended wire for the battery is that its terminals are not connected to
any additional inverter.

2.4 Dry contact instruction

Dry contact parameter
Rated Value:5A/30VDC
Maximum Value:0.5A/60VDC
1) Control the utility/generator ON/OFF via the
(Utility/Generator) dry contact
Utility/Generator start-up Voltage (V
Voltage
Utility/Generator stop Voltage (V
Battery Voltage (V
)
BAT
 Start-up the Utility/Generator: V
 Stop the Utility/Generator: V
 Before starting or stopping the Utility/Generator via the (Utility/Generator) dry
contact, you shall set the switch to the ON position.
 The VON and VOFF can be set via the PC software. The Battery Control Voltage
CAUTION
Parameters refer to chapter
2) Control the load first disconnection and second disconnection.
Battery Voltage (V
)
BAT
Under Voltage Warning Voltage (V
Under Voltage Warning Recover Voltage (V
Low Voltage Disconnect Voltage (V
Low Voltage Reconnect Voltage (V
 (Utility/Generator) dry contact OFF interface
≤V
: The (Utility/Generator) dry contact OFF interface controls the load ❶ first disconnection.
V
BAT
UVW
≥V
: (Utility/Generator) dry contact OFF interface controls the load ❶ first connection.
V
BAT
UVWR
 (Load) dry contact
≤V
: The (Load) dry contact controls the load ❷ second disconnection.
V
BAT
LVD
≤V
: The (Load) dry contact controls the load ❷ second connection.
V
BAT
LVR
) = Under Voltage Warning
ON
) = Under Voltage Warning Recover Voltage
OFF
<V
.
BAT
ON
> V
.
BAT
OFF
3.4
Setting.
)
UVW
)
UVWR
)
LVD
)
LVR
8