4.6.4.2 - PROCEDURE OF USE WITH PETERSON MODEL PRESSURE OUTLET
ATTENTION!
The maximum operating pressure for a Peterson model standard pressure outlet is 10 bar.
NOTE!
The pressure gauge (E) and the ring nut (D) are not included in the standard scope of supply and are sup-
plied only on request.
To use a Peterson model pressure outlet (A), proceed as follows:
Step
Action
1
Remove the closing cap (B).
Fit the pin (C) until the connection with the gas chamber of the outlet body is made, then lock it through the
ring nut (D).
2
NOTE!
The pin (C) is not present on the regulator but is an accessory of the pressure outlet.
3
Read the pressure measured on the pressure gauge (E).
4
After reading, loosen the ring nut (D) to unlock the pin (C).
5
Remove the pin (C).
6
Put the closing cap (B) back in place.