4.6 -
SAFETY DEVICES
To prevent the safety devices from tripping during normal service (when there are no faults at user level):
•
do not exceed the maximum capacity values of the gearbox;
•
do not feed the gearbox with pressures lower than the minimum values specified;
•
do not purge of the downstream line with the gearbox installed.
4.6.1 - SLAM-SHUT VALVE FOR MAXIMUM DOWNSTREAM PRESSURE
NOTE!
If the valve trips, service will be interrupted.
The slam-shut valve for maximum downstream pressure (A) is a safety device that remains open in normal service
conditions and automatically and completely closes the gas flow when the maximum downstream pressure exceeds the
calibration values.
35
Fig. 4.3. Slam-shut valve for maximum pressure
LOW-PRESSURE GAS REGULATOR
A
|
DESCRIPTION AND OPERATION
Use, maintenance and warning manual
|
REV. 00
EN