Graco ProMix PD3K Plus Operation page 85

Proportioner for automatic spray applications
Table of Contents

Advertisement

Pump Screen
Screen - - - Valve
Valve Assignment
Pump
Pump
Screen
Valve
Figure 65 Pump Screen, Valve Assignment
Figure 66 Solenoid Location Enumeration
3A6287E
Assignment
Assignment
This screen allows the user to assign each individual
color change valve solenoid in the system to a unique
location. The list of valves will automatically populate
based on the settings that apply to the pump. A
description of the valve includes what stack it belongs
to, the material identification, and a specific gun or
pump designator, if that applies.
NOTE: Some remote stack valves may be shared by
NOTE:
NOTE:
more than one pump. They will show up on the valve
list for all pumps to which they apply.
All color change valves require a valid location
be assigned for the system to be able to operate
properly. There are two columns that determine the
solenoid location. The left column is the color change
module number. This number must be between 1
and 8 and should reflect the dip switch settings on
one of the color change boards (see manual 332455
for more details on dip switch settings). The second
column is the solenoid location, and this number
must be between 1 and 18. The following figure
shows the solenoid location enumeration.
Setup Mode Screens
85

Advertisement

Table of Contents
loading

Table of Contents